Advanced Automation & Engineering Ltd.

Fire Detection & Safety Systems

Addressable & conventional detection, alarm/notification, and suppression systems — engineered, installed, and maintained in line with NFPA and BNBC.

Protect People, Assets & Operations

AAEL designs and delivers complete fire safety solutions for industrial, commercial and high-rise facilities. From risk assessment and device zoning to cable routing, integration and evacuation planning, we build systems that pass inspections and perform in real emergencies.

What We Do

Detection & Alarm

Addressable / conventional fire alarm systems with zoning, cause & effect logic, and clear notification strategies.

Suppression

Clean agent, CO₂, water mist or sprinkler tie-ins with releasing panels, interlocks and room integrity considerations.

Integration

BMS/FA interface, lifts/HVAC shutdown, door magnets, gas release, and voice evacuation systems.

Our Turnkey Scope

  • Risk assessment, zoning & device selection
  • Layout drawings, loop calculations & cable routing
  • Control panel programming & cause–effect matrix
  • Supply, installation, testing & commissioning
  • Integration with BMS, lifts, HVAC & access control
  • Training, drills & maintenance schedules
Documentation packs include device lists, as-built drawings, test sheets, and compliance statements for inspection.

Key Components We Provide

  • Addressable/conventional panels, modules & loop cards
  • Smoke/heat/beam detectors & manual call points
  • Sounders, strobes, voice evac & visual indicators
  • Releasing panels, nozzles, cylinders (clean agent/CO₂)
  • Fire cable, glands, junctions, labels & signage
  • Ancillary interfaces for lifts, HVAC, access & doors

Our Delivery Process

01

Survey

Risk review, occupancy & hazard classification.

02

Design

Zoning, device layout & cause–effect logic.

03

Procure

Approved equipment & QA checks.

04

Install

Cable routing, mounting & labeling.

05

Commission

Loop tests, device programming & integration.

06

Handover

Training, drills & maintenance plan.

Standards & Guidelines

Designs and installations reference the following codes and local requirements:

NFPA 72 / 2001 BNBC IEC / BS Local Fire Service Manufacturer Manuals

Handover Documents

  • As-built drawings, device lists & addressing sheets
  • Loop tests, functional & integration test results
  • Datasheets, certificates & programming backups
  • Training records & maintenance schedules

Frequently Asked Questions

Addressable systems provide faster pinpointing of alarms/troubles and better scalability; conventional works for smaller/simple layouts. We recommend based on risk, size and future expansion.
Yes. We program evacuation logic and integrate with lifts, HVAC and access control, including fail-safe interlocks and voice evacuation.
Absolutely. We prepare the documentation bundle, attend inspections, and demonstrate system functions for sign-off.

Need a compliant fire system?

Get a tailored design, bill of materials and commissioning plan for your facility.

Request Fire Safety Consultation